OXINIUM

Oxidized Zirconium for Hips

OXINIUM femoral heads for hips

Product information

OXINIUM, oxidized zirconium is a metallic alloy with a ceramic surface that provides wear resistance without brittleness. OXINIUM material combines the best of both metal and ceramics.  

  Download and view the OXINIUM for hips brochure.  

The combination of OXINIUM heads on XLPE liners offers:

  • No risk of fracture, chipping or squeaking
  • Lower wear rates


In addition, OXINIUM heads and XLPE liners are available in a wide variety of head sizes and neck offsets, which allow you the intraoperative flexibility to help restore a full range of motion.
For information about hip products that are made of OXINIUM and XLPE, visit the

VERILAST Technology section

 

OXINIUM heads on XLPE liners: no fracture, chipping or squeaking

The ceramic surface of OXINIUM heads is not a coating, so it cannot chip or flake. The original metal surface is transformed into a ceramic through thermal processing, providing you with an unbreakable ceramic on the market that is not a coating. 1,2,3  
The ceramic surface of OXINIUM heads is integral with the metal alloy which allows OXINIUM heads to provide ceramic wear performance without the risk of fracture. 2,4,5 Whether it is fracture, chipping or squeaking that you are concerned about, OXINIUM heads on XLPE liners address all of these concerns.

  OXINIUM heads on XLPE liners: lower risk of osteolysis    

Smith & Nephew XLPE acetabular liners produce less wear particles than other cross-linked polyethylenes. 12,13,14 When combined with OXINIUM heads, wear debris is further reduced in comparison with standard CoCr heads.  
Simulator results utilizing the active high demand patient profile demonstrate that OXINIUM heads outperform CoCr heads on XLPE. OXINIUM heads minimize the material-related risks associated with other advanced bearings, while meeting the requirements of active patients. Whether it is the demands of active patients or prosthesis longevity that you are concerned about, OXINIUM heads on XLPE liners are a great choice. 16

  References
1. Hunter, G., Dickinson, J., Herb, B., et al. (2005). Creation of oxidized zirconium orthopaedic implants. J. ATSM Int.,

2 (7). 2. Sheth, N., Lementowski, P., Hunter, G., Garino, J. (2008). Clinical Applications of Oxidized Zirconium. J. Surgical Orthopaedic Advances, 17(1).

3. Hunter, G. (2001) Adhesion testing of oxidized zirconium. Trans. 27th Ann. Mtg. Soc. Biomaterials, Society for Biomaterials, Minneapolis, MN, 540.

4. Hobbs, L., Rosen, V., Mangin, S., et al. (2005). Oxidation microstructures and interfaces in the oxidized zirconium knee. J. Appl. Ceram. Tech., (2), 221-246.

5. Sprague, J., Salehi, A. Tsai S., et al., Mechanical behavior of zirconia, alumina, and oxidized zirconium modular heads. In ISTA 2003, vol. 2, edited by S. Brown, I. C Clarke, A. Gustafson, International Society for Technology in Arthroplasty, Birmingham, AL, 2004.

6. Hallab, N. (2004). Lympohocyte transformation testing for quantifying metal-implant-related hypersensitivity responses. Dermatitis, 15 (2), 82-92.

7. Kovacs, P., Davidson J., Chemical and electrochemical aspects of the biocompatibility of titanium and its alloys. In American Society for Testing and Materials: Medical Applications of Titanium and Its Alloys, pp. 163-178, edited by S. A. Brown, J.E. Lemons, ASTM STP 1272, American Society for Testing and Materials, West Conshohocken, PA 1996.

8. Hallab, N., Merritt, K., Jacobs, J. (2001). Metal sensitivity in patients with orthopaedic implants. Journ. Bone Joint Surg., 83 (A), 428-436.

9. Marek, M., Pawar, V., Tsai. S., et al. (2006). Galvanic corrosion evaluation of Zr-2.5Nb coupled with orthopaedic alloys. In Medical Device Materials, 3, (pp. 195-201). Materials Park, OH: R. Venugopalan, M. Wu, ASM International Edition.

10.  Nasser, S., Mott, M., Wooley, P. (2006). A prospective comparison of ceramic and oxinium TKA components in metal hypersensitivity patients. Proceedings of the Annual Meeting of the American Academy of orthopaedic Surgeons, (pp. 194) San Diego, CA.

11. Lhotka, C., Szekerea, T., Steffan, T., Zhubar, K., and Zweymuller, K. 2003). Four year study of cobalt and chromium blood levels in patients managed with two different metal on metal total hip replacements. J. Ortho Research, 21 (2), 189-195.

12. Good, V., Ries, M., Barrack, Rl, et al. (2003). Reduced wear with oxidized zirconium femoral heads. J. Bone Joint Surg., 85 (A suppl 4) 105-110.

13. Ries, M., Scott, M., Jani, S. (2001). Relationship between gravimetric wear and particles generation in hip simulators: conventional compared with cross-linked polyethylene. J. Bone Joint Surg. Am., 83, S116-122.

14. Scott, M., Morrison, M., Mishra, S., Jani, S. (2002). A method to quantify wear particle volume using atomic force microscopy. ORS Transactions, 27, 132.

15. Smith & Nephew. (2008). Smith & Nephew (Internal Report). Parikh, et. al.

16. M .G. Li, Z.K. Zhou, D.J. Wood, S.M. Rohrl, J.L. Loppolo, and B. Nivbrandt. (2006) Low wear with high-cross linked polyethylene especially in combination with Oxinium heads. A RSA evaluation. Trans. Orthop. Res. Soc., 31, 643.

Design

The forces generated as a knee or hip goes through its range of motion require a strong material that can withstand repeated sliding and rotating. High fatigue strength and toughness are needed. The ideal TJA (total joint arthroplasty) material should also be smooth and resist abrasion to minimize generation of wear particles. This combination of properties has been difficult to find - until the introduction of a revolutionary material for joint implants - OXINIUM Oxidized Zirconium.


 OXINIUM Design for total joint

While a ceramic implant provides a smooth, abrasion-resistant articular surface, it has poor fracture toughness and may shatter when impacted. On the other hand, metal implants have an excellent fracture toughness but tend to roughen and scratch over time, gouging the polyethylene and producing particles. 1,2

OXINIUM Oxidized Zirconium for hips and knees design


Efforts to reduce the wear rate of metal implants through surface modifications have had difficulty with durability. Coatings can crack, chip or peel, especially when damaged. Through a patented process, oxygen is absorbed into zirconium metal, actually transforming the surface to ceramic while the rest of the material remains metal to retain its strength. The result is in a superior bearing surface. Please review the information within this site to learn more about this superior option for TJA or call your local Smith & Nephew sales representative.

 

Wear in Total Joint Arthroplasty

Wear of polyethylene components has often been reported in TJA to be a primary cause of complications and failure. Retrieval analyses and published articles support that a high percentage of inserts and patellas develop a significant wear pattern clinically.


Wear In THA

In THA, the reduction in friction and wear with the OXINIUM bearing coupling is significant because aseptic loosening is a leading cause of implant failure, and wear debris is the leading cause of aseptic loosening. While virtually all advanced bearing couplings produce nearly immeasurable wear, metal-on-metal couplings produce cobalt and chromium ions. Ceramic couplings risk fracture.
With OXINIUM femoral heads, low wear reduces the chances of aseptic loosening and may extend the life of the joint. The OXINIUM material may offer extended joint life through reduced wear and friction.

Wear in TKA

In eight TKA retrieval studies covering the last 20 years, polyethylene wear was identified in over 50% of the 3,300-plus knees examined.
More than 10 publications in the past 10 years have linked polyethylene wear to complications and failure of TKA. 7-17
For additional information, please contact your local rep.

References

1. R.H. Zimlich, M. Levesque, W. Jones, H.D. Schutte, Jr., B.J. Livingston, W. Sauer, M. Spector, and K. Weaver, "In-vitro and in-vivo effect of particulate debris on TKA articulating surfaces", scientific exhibit SE038, 65th Ann. Mtg. Am. Acad. Orthop. Surg., New Orleans, LA, March 19-23, 1998.
2. M. Levesque, B.J. Livingston, W.M. Jones, and M. Spector, "Scratches on condyles in normal functioning total knee arthroplasty", Trans. 44th Ann. Mtg. Orthop. Res. Soc., Orthopaedic Research Society, Chicago, IL, 1998, p. 247.
3. M. Long, L. Riester, and G. Hunter, “Nano-hardness measurements of oxidized Zr-2.5Nb and various orthopaedic materials”, Trans. Soc. Biomaterials, 21, 1998, p. 528.
4. G. Hunter and M. Long, “Abrasive wear of oxidized Zr-2.5Nb, CoCrMo, and Ti-6Al-4V against bone cement”, 6th World Biomaterials Cong. Trans., Society For Biomaterials, Minneapolis, MN, 2000, p. 835.
5. G. Hunter, “Adhesion testing of oxidized zirconium”, Trans. Soc. Biomaterials, 24, 2001, p. 540.
6. S. Tsai, J. Sprague, G. Hunter, R. Thomas, and A. Salehi, “Mechanical testing and finite element analysis of oxidized zirconium femoral components”, Trans. Soc. Biomaterials, 24, 2001, p. 163.
7. L. Que, L.D.T. Topoleski, and N.L. Parks, "Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints", J. Biomed. Mater. Res., 53 (1), 1999, pp. 111- 118.
8. J.G. Lancaster, D. Dowson, G.H. Isaac, and J. Fisher, "The wear of ultra-high molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement", Proc. Instn. Mech. Engrs., 211 (H1), 1997, pp. 17-24.
9. J. Fisher, P. Firkins, E.A. Reeves, J.L. Hailey, and G.H. Isaac, "The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene", Proc. Instn. Mech. Engrs., 209 (H4), 1995, pp. 263-264.
10. J.L. Hailey, E. Ingham, M. Stone, B.M. Wroblewski, and J. Fisher, "Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests; the influence of counterface roughness", Proc. Instn. Mech. Engrs., 210 (H1), 1996, pp. 3-10.
11. B. Weightman and D. Light, "The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethylene", Biomaterials, 7 (1), 1986, pp. 20-24.
12. H. Oonishi, Y. Hanatate, E. Tsuji, and H. Yunoki, "Comparisons of wear of UHMW polyethylene sliding against metal and alumina in total knee prostheses", Bioceramics, H. Oonishi, H. Aoki, and K. Sawai (eds.), Ishiyaku EuroAmerica, Tokyo, 1989, pp. 219-224.
13. J.A. Davidson, "Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear", Clin. Orthop., 294, 1993, pp. 361-378.
14. J. Fisher and D. Dowson, "Tribology of total artificial joints", Proc. Instn. Mech. Engrs., 205 (H2), 1991, pp. 73-79.
15. M. Jasty, C.R. Bragdon, K. Lee, A. Hanson, and W.H. Harris, "Surface damage to cobalt-chrome femoral head prostheses", J. Bone Joint Surg., 76-B (1), 1994, pp. 73-77.
16. R.Barrack, F.Castro, E. Szuszczewicz, T.Schmalzried, “Analysis of Retrieved Uncemented Porous-Coated Acetabular Components in Patients With and Without Pelvic Osteolysis”, Orthopedics, 25:12, 2002, pp. 1373-1378.
17. Sychterz CJ, Engh CA Jr, Swope SW, McNulty DE, Engh CA, “Analysis of prosthetic femoral heads retrieved at autopsy”, Clin Orthop. 1999 Jan; (358):223-34.
18. R.A. Poggie, J.J. Wert, A.K. Mishra, and J.A. Davidson, “Friction and wear characterization of UHMWPE in reciprocating sliding contact with Co-Cr, Ti-6Al-4V and zirconia implant bearing surfaces”, Wear and Friction of Elastomers, ASTM STP 1145, R. Denton and M.K. Keshavan (eds.), American Society for Testing and Materials, Philadelphia, PA, 1992, pp. 65-81.
19. A.M. Patel and M. Spector, “Tribological evaluation of oxidized zirconium using an articular cartilage counterface: a novel material for potential use in hemiarthroplasty”, Biomaterials, 18 (5), 1997, pp. 441-447.
20. M. Spector, M.D. Ries, R.B. Bourne, W.S. Sauer, M. Long, and G. Hunter, “Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components”, J. Bone Joint Surg., 83-A (S2), 2001, pp. 80-86.
21. N.J. Hallab, K. Merritt, and J.J. Jacobs “Metal sensitivity in patients with Orthopaedic implants”, J. Bone Joint Surg., 83-A, March, 2001, pp. 428-436.
22. G. Hunter, W.M. Jones, and M. Spector, “Oxidized zirconium”, Total Knee Arthroplasty, J. Bellemans, M.D. Ries, and J. Victor (eds.), Springer Verlag, Heidelberg, Germany, 2005, pp. 370-377.
23. Jani et al, ORS, 49, 2002.
24. Good V, Ries M, Barrack RL, Widding K, Hunter G, Heuer D, Reduced Wear with Oxidized Zirconium Femoral Heads, JBJS in print, 2003.
25. M.D. Ries, W.L. Sauer, S.A. Banks, M. Anthony, and K. Weaver, "Effect of femoral component scratches on wear in total knee arthroplasty", Am. Acad. Orthop. Surg. 66th Ann. Mtg. Proc., American Academy of Orthopaedic Surgeons, Rosemont, IL, 1999, p. 231.
26. M. Ries, S. Banks, W. Sauer, and M. Anthony, "Abrasive wear simulation in total knee arthroplasty", Trans. 45th Ann. Mtg. Orthop. Res. Soc., Orthopaedic Research Society, Chicago, IL, 1999, p. 853.

Want more product information?

Contact Customer Service at 1-800-238-7538 or

 

Inquire online

This information is intended for health care professionals in the United States only.

Caution: US Federal law restricts the sale of these devices to or on the order of a physician.