PERI-LOC VLP

About


Variable-Angle Locked Plating System

PERI-LOC VLP◊ offers a stable, low profile means of fixation for fractures of the fibula and partial articular fractures of the tibia. The PERI-LOC VLP plating system is designed specifically to treat fibula fractures and partial articular tibia fractures. It gives surgeons the freedom to control fixation and helps restore not just the patient's anatomy but their lifestyle.

PERI-LOC VLP options


3.5mm Lateral Distal Fibula Locking Plate
• Distal screw cluster and low plate profile provide stable periarticular fixation
•2.0mm - 1.7mm proximal to distal plate thickness transition
• Left and right specific

3.5mm Posterolateral Distal Fibula Locking Plate
• Scalloped for syndesmotic screw placement outside the plate without compromising plate position
• 1.5mm - 0.9mm proximal to distal plate thickness transition
• Left and right specific
• 8° distal helical twist accommodates the posterolateral anatomy of the distal fibula
• Rounded distal edges to minimize peroneal nerve irritation

3.5mm Medial Distal Tibia Locking Plate
• Smooth distal tip minimizes soft tissue irritation over the medial malleolus
• 2.0mm - 1.5mm proximal to distal plate thickness transition
• Contour facilitates a medial approach to distal tibia fractures in the saggital plane
• Left and right specific

3.5mm One-Third Locking Tubular Plate
• Low-profile buttress plate for fractures of the distal fibula
• Consistent 1.5mm plate thickness

3.5mm Anterior Distal Tibia Locking Plate
• Scalloped to allow lag screw placement without compromising plate position
• Contour facilitates an anterior approach to distal tibia fractures in the coronal plane
• Consistent 1.5mm plate thickness
• Left and right specific


3.5mm Posterior Distal Tibia Locking Plate
• Scalloped to allow lag screw placement without compromising plate position
• Contour facilitates a posterior approach to distal tibia fractures in the coronal plane
• Consistent 1.5mm plate thickness
• Left and right specific

3.5mm Lateral Proximal Tibia Locking Plate
• Scalloped to allow lag screw placement without compromising plate position
• 1.5mm - 2.0mm proximal to distal plate thickness transition
• Left and right specific
• 3° AP radius of curvature optimizes plate coverage down the tibial shaft and proximal screw position

3.5mm Posteromedial Proximal Tibia Locking Plate
• Contoured to provide a stable buttress platform for fractures of the medial tibial plateau
• Consistent plate thickness:
1.5mm = 4 hole
2.0mm = 7 hole
• Left and right specific