SPORTS MEDICINE
INTELLIO◊ SHIFT◊ System
Twice the resection ability in one powerful solution, with the ability to shift seamlessly between radiofrequency (RF) and mechanical resection.1-3
Accelerate your OR
Developed to help you reclaim space in your busy operating room, the INTELLIO SHIFT System combines two resection methods into one device. With three ways to switch between RF and mechanical resection−the integrated touchscreen, hand control or combination foot pedal−the surgical team has full control1-3 of pace-setting COBLATION◊ and DYONICS◊ Technologies in one system:
- Radiofrequency (RF) resection: The controlled plasma field and range of COBLATION Technology Wands offer speed and precision at the touch of a button*4,5
- Mechanical resection: Efficient soft tissue resection6 with DYONICS PLATINUM Blades. Designed to retain sharpness, with minimal clogging during soft tissue resection and low metal debris generation**7,8
Two resection technologies in one controller
Control with the combination foot pedal
1. Adjust ablation levels or shaver speeds.
2. Shift between connected devices.
3. Lavage/rinse.
4. Ablate/blade reverse.
5. Coagulate/blade oscillate.
6. VAC mode/blade forward
Surgical videos
COBLATION and FLOW-IQ Technology
Designed to offer speed and precision at the touch of a button,*4,5 COBLATION Technology is backed by more than 20 years of clinical use.9 With the ability to seamlessly choose from three distinct modes (low, medium, high) it offers a low temperature alternative to other resection methods.
DYONICS PLATINUM Resection Technology
With high torque performance and a working range of 4,000 and 10,000 RPM,14 DYONICS PLATINUM Blades and Burrs are designed to improve resection quality. Low clogging and a low risk of metal debris during soft tissue resection,**8 provide efficient resection that may help minimize patients’ time under anesthesia.6
DYONICS Resection Technology
Reference Materials
Clinical evidence
Medical Education
Related Products
Disclaimers
*As demonstrated in benchtop testing.
**As Demonstrated ex vivo and in cadaveric studies.
*** As Demonstrated ex vivo.
****Demonstrated ex vivo; cell damage may vary depending on protocol used.
PLATINUM Blades 30-day satisfaction guarantee not available in all countries. Please check availability and requirements. Return the unused portion of the PLATINUM Blade
order for a credit. Credit and return goods authorization must be requested within 30 days of purchase.
Wireless connectivity available in certain countries only. Please check availability.
Products may not be available in all markets because product availability is subject to the regulatory and/or medical practices in individual markets. Please contact your Smith+Nephew representative or distributor if you have questions about the availability of Smith+Nephew products in your area. For detailed product information, including indications for use, contraindications, precautions and warnings, please consult the product’s applicable Instructions for Use (IFU) prior to use.
Citations
- Smith+Nephew 2023. Internal Report. P/N 10092266 Rev. A.
- Smith+Nephew 2023. Internal Report. P/N 10092118 Rev. A.
- Smith+Nephew 2023. Internal Report. 100914436 Rev. A.
- Smith+Nephew 2019. Internal Report. P/N 106506-01 Rev A.
- Amiel D, et al. Arthroscopy. 2004;20(5):503-510.
- Smith+Nephew 2021. Internal Report. EO.SPM.PCS031.001 v1.
- Smith+Nephew 2021. Internal Report. EO.SPM.PCS031.002 v1.
- Smith+Nephew 2021. Internal Report. EO.SPM.PCS031.003 v1.
- Smith+Nephew 2017. Internal Report. P/N 5291999.
- Smith+Nephew 2023. Internal Report. P/N 126735 Rev. A.
- ArthroCare 2014. Internal Report. P/N 52918-01.
- ArthroCare 2015. Internal Report. P/N 65200-01 Rev. A.
- Smith+Nephew 2019. Internal Report. P/N 88079-01 Rev C.
- Smith+Nephew 2021. Internal Report. 15011440 Rev A.