Global

‡ In these countries please contact our distributor

PERI-LOC VLP

Variable-Angle Locked Plating System

Algemeen

PERI-LOC VLP Variable-Angle Locked Plating System
“Increasing surgical freedom Restoring patient function”

PERI-LOC VLP gives you the freedom to control fixation and helps restore not just the patient's anatomy, but their lifestyle.

  • Freedom to choose plate position
  • Freedom to choose stability in osteopenic bone
  • Improves patient comfort
  • Restore patient joint
  • Restore patient anatomy
  • Options for Distal Fibula, Distal Tibia and Proximal Tibia




Distal Fibula


3.5mm Lateral Distal Fibula Locking Plate

  • Distal screw cluster and low plate profile provide stable periarticular fixation 
  • 2.0mm - 1.7mm proximal to distal plate thickness transition


3.5mm Posterolateral Distal Fibula Locking Plate

  • Scalloped for syndesmotic screw placement outside the plate without compromising plate position 
  • 1.5mm - 0.9mm proximal to distal plate thickness transition 
  • Left and right specific 
  • 8° distal helical twist accommodates the posterolateral anatomy of the distal fibula 
  • Rounded distal edges to minimize peroneal nerve irritation 



Distal Tibia


3.5mm Anterior Distal Tibia Locking Plate

  • Scalloped to allow lag screw placement without compromising plate position 
  • Contour facilitates an anterior approach to distal tibia fractures in the coronal plane 
  • Consistent 1.5mm plate thickness 
  • Left and right specific


3.5mm Medial Distal Tibia Locking Plate

  • Smooth distal tip minimizes soft tissue irritation over the medial malleolus 1
  • 2.0mm - 1.5mm proximal to distal plate thickness transition 
  • Contour facilitates a medial approach to distal tibia fractures in the sagittal plane 
  • Left and right specific


3.5mm Posterior Distal Tibia Locking Plate

  • Scalloped to allow lag screw placement without compromising plate position 
  • Contour facilitates a posterior approach to distal tibia fractures in the coronal plane 
  • Consistent 1.5mm plate thickness 
  • Left and right specific


3.5mm One-Third Locking Tubular Plate

  • Low-profile buttress plate for fractures of the distal fibula 
  • Consistent 1.5mm plate thickness




Proximal Tibia



3.5mm Lateral Proximal Tibia Locking Plate

  • Scalloped to allow lag screw placement without compromising plate position 
  • 1.5mm - 2.0mm proximal to distal plate thickness transition 
  • Left and right specific 
  • 3° AP radius of curvature optimizes plate coverage down the tibial shaft and proximal screw position


3.5mm Posteromedial Proximal Tibia Locking Plate

  • Contoured to provide a stable buttress platform for fractures of the medial tibial plateau 
  • Consistent plate thickness: 1.5mm = 4 hole 2.0mm = 7 hole 
  • Left and right specific



Referencies

1. Case Study: Bicondylar tibial plateau fracture Michael J. Prayson, MD